当前位置:首页 > 文献方案 > 应用文献 > 通过在线乙烯分析仪和光合仪检测紫外线诱导的植物胁迫
文章导读
在Solenostemon scutellarioides杂交种上测定根区的光合作用和蒸腾作用以及乙烯排放量(co.Coleus blumei)广藿香)。应该弄清楚这些参数是否适合检测UV诱导的植物胁迫。用来自HPS灯的人造光处理实验植物,其具有额外的UV-A和UV-B光。在光合作用和蒸腾测量的基础上,不可能对植物的胁迫状态做出明确的陈述。根据其他研究,无应激植物的乙烯值具有明显的日常节律

Detection of UV Induced Plant Stress by CO2/H2O Gas Analysis and Online Ethylene Measurement

通过在线乙烯分析仪和光合仪检测紫外线诱导的植物胁迫
N. Domuratha, D. Brohm and F.-G. Schröder
Faculty for Agriculture / Landscape Management
University of Applied Sciences Dresden
01326 Dresden
Germany
Keywords: Solenostemon scutellaroides, injury-free measurement, photosynthesis rate, C2H4


Abstract
Photosynthesis and transpiration as well as ethylene emissions in the root zone were measured on Solenostemon scutellarioides hybrids (syn. Coleus blumei
Benth). It should be figured out whether these parameters are suitable to detect UV induced plant stress. The experimental plants were treated with artificial light from
HPS lamps with additional UV-A and UV-B light. It was not possible to make clear statements about the stress status of the plants on the basis of the photosynthesis and transpiration measurements. The ethylene values of unstressed plants were in a clear daily rhythm in accordance with other studies. It was not possible to reproduce the switching cycles of the UV lamps in the ethylene values. Watering, both with nutrient solution and deionised water, caused changes in the C2H4-budget. The HPS + UV-A variant responded with the strongest amplitude to nutrient solution. In the subsequent period mean values remained at 120% of the original ethylene levels for several hours.

在Solenostemon scutellarioides杂交种上测定根区的光合作用和蒸腾作用以及乙烯排放量(co.Coleus blumei)广藿香)。应该弄清楚这些参数是否适合检测UV诱导的植物胁迫。用来自HPS灯的人造光处理实验植物,其具有额外的UV-A和UV-B光。在光合作用和蒸腾测量的基础上,不可能对植物的胁迫状态做出明确的陈述。根据其他研究,无应激植物的乙烯值具有明显的日常节律。不可能在乙烯值中再现UV灯的开关循环。用营养液和去离子水浇水引起C 2 H 4的变化-预算。HPS + UV-A变体对营养液的响应幅度最强。在随后的时期内,平均值保持在原始乙烯水平的120%,持续数小时。

The CIRAS-1 (PP Systems) with the leaf cuvette PLC B (settings: RS ratio 100, 200 ml min-1 flow rate, 380 ppm CO2) was used for the CO2/H2O gas exchange measurements. The values were taken from the three youngest unfolded leaves per experimental plant at each run. Measurements were made on the first and fifth day at the same daytime. The UV light was switched on already 30 minutes at the appropriate plots. The used portable devise ETH-1010 (Fluid Analytics) provides real-time measurements of ethylene in air at concentrations as low as 10 ppb. The measurement unit sampled about a 200 ml air within an interval of three minutes. A multiposition valve was pre-connected to the ETH-1010 to perform several measurements in a cycle. The multiposition valve switched four reading points. This led to measurement cycles of about 12 minutes. Three samples from the root area of experimental plants and one sample of greenhouse air (control point) were analysed at each cycle. Random tests of the accuracy were made by connecting a calibration gas to the control point.

使用CIRAS-1(PP Systems)和叶室PLC B(设置:RS比100,200 ml min-1流速,380 ppm CO2)进行CO2/H2O气体交换测量。这些值取自每株实验植物在每次运行时最年轻的三片展开叶。在同一天的第一天和第五天进行测量。在适当的位置,紫外线灯已经打开30分钟。使用的便携式乙烯分析仪 ETH-1010(Fluid Analytics)提供了空气中乙烯浓度低至10ppb的实时测量。测量单元在三分钟的间隔内对大约200毫升空气进行采样。一个多位置的阀门被预先连接到ETH-1010上,在一个周期内进行多次测量。多位置阀切换了四个读数点。大约12分钟的测量周期。对试验植物根区的3个样品和温室空气(控制点)的1个样品进行了每个周期的分析。通过将校准气体连接到控制点,对精度进行随机测试。