服务热线:400-028-9008
您好!欢迎访问图拉扬公司![登录] [注册]
我的订单

当前位置:首页 > 实验技术 > 离子迁移谱/质谱 > 实时直接分析-质谱法测定人血清中的抗真菌药物:一项概念验证研究
文章导读
实时直接分析(DART)是一种软电离技术,使用氦气、氩气或氮气等加热气体产生一系列电离的大气分子,随后将生物样品中的分析物电离。目的:在这项评估人血清中选定抗真菌药物的概念验证研究中,使用 Bruker EVOQ® DART-TQ+ 对 5-氟胞嘧啶(5FC)、伊曲康唑(ITR)、羟基伊曲康唑(OH-ITR)、艾沙康唑(ISV)、酮康唑(KETO)、氟康唑(FLU)和泊沙康唑(POSA)作为 DART 候选药物进行了评估。

Direct Analysis in Real Time-Mass Spectrometry Measurement of Antifungals in Human Serum: A Proof-of-Concept Study
Julie A Ray et al.


Abstract

INTRODUCTION: Direct analysis in real time (DART) is a soft ionization technique that uses a heated gas such as helium, argon, or nitrogen to generate a cascade of ionized atmospheric molecules that subsequently ionize analytes in biological samples. OBJECTIVES: In this proof-of-concept study evaluating selected antifungals in human serum, 5-fluorocytosine (5FC), itraconazole (ITR), hydroxyitraconazole (OH-ITR), isavuconazole (ISV), ketoconazole (KETO), fluconazole (FLU), and posaconazole (POSA) were assessed as DART candidates using a Bruker EVOQ® DART-TQ+.

METHODS: Human serum samples were extracted using protein precipitation or liquid–liquid extraction. Quantification was performed by DART tandem mass spectrometry (DART-MS/MS) with internal standards. Precision and linearity across individual analytical measurement ranges (AMRs) were evaluated with rapid sample acquisition (0.24 min linear scans), and the results were compared with those obtained using validated LC-MS/MS methods.

RESULTS: Linearity and precision were acceptable for all evaluated compounds. Good agreement with LC-MS/MS was observed for 5FC, ITR, OH-ITR, and FLU, with slopes ranging from 0.875 to 1.112 and correlation coefficients (r) ≥ 0.949. POSA extraction by protein precipitation resulted in high bias; however, liquid–liquid extraction or the use of an alternative ion transition reduced bias to <7%. DART replicates demonstrated coefficients of variation <15%. All samples met ion-ratio tolerance criteria of ±50%.

CONCLUSION: This proof-of-concept study demonstrates the feasibility of quantitative antifungal measurement in human serum using DART-MS/MS with simple sample preparation. A moderate linear association with bias for POSA was likely attributable to matrix effects. More selective sample preparation may improve DART accuracy. Overall, DART-MS/MS shows promise as a rapid, high-throughput alternative to conventional LC-MS/MS.
摘要
引言:实时直接分析(DART)是一种软电离技术,使用氦气、氩气或氮气等加热气体产生一系列电离的大气分子,随后将生物样品中的分析物电离。目的:在这项评估人血清中选定抗真菌药物的概念验证研究中,使用 Bruker EVOQ® DART-TQ+ 对 5-氟胞嘧啶(5FC)、伊曲康唑(ITR)、羟基伊曲康唑(OH-ITR)、艾沙康唑(ISV)、酮康唑(KETO)、氟康唑(FLU)和泊沙康唑(POSA)作为 DART 候选药物进行了评估。

方法:采用蛋白沉淀或液-液萃取法提取人血清样品。使用 DART 串联质谱(DART-MS/MS)并结合内标进行定量。在快速样品采集(0.24 min 线性扫描)条件下评估了各分析测量范围(AMR)内的精密度和线性,并将结果与使用已验证的 LC-MS/MS 方法获得的结果进行了比较。

结果:所有评估化合物的线性和精密度均可接受。5FC、ITR、OH-ITR 和 FLU 与 LC-MS/MS 显示出良好一致性,斜率范围为 0.875 至 1.112,相关系数(r)≥ 0.949。采用蛋白沉淀提取 POSA 导致高偏差;然而,液-液萃取或使用替代离子跃迁可将偏差降低至 <7%。DART 重复测定的变异系数 <15%。所有样品均满足 ±50% 的离子比耐受标准。

结论:这项概念验证研究表明,使用 DART-MS/MS 并结合简单样品前处理对人血清中的抗真菌药物进行定量测定是可行的。POSA 存在中等线性相关并伴有偏差,可能归因于基质效应。更具选择性的样品前处理可能会提高 DART 的准确性。总体而言,DART-MS/MS 有望成为传统 LC-MS/MS 的一种快速、高通量替代方法。


2.3. DART-MS/MS Instrumentation and Conditions

To identify unique MS/MS transitions, the automated multiple reaction monitoring (MRM) optimization function was used to directly infuse standard solutions of analytes and associated internal standards into an EVOQ® DART-TQ+ (Bremen, Germany) triple-quadrupole MS fitted with a heated electrospray ionization (HESI) source. Five transitions per analyte were collected for use in DART-MS/MS optimization work. For DART-MS/MS analysis, the MS was fitted with an integrated DART JumpShot® HTS systems ionization source (Bremen, Germany). To identify optimal MS/MS transitions, 3.5 µL methanolic aliquots of standard solutions of analytes and associated internal standards were spotted onto QuickStrip HTS-96 Sample Cards (Bremen, Germany), dried under nitrogen for 15 min at 40 °C, and analyzed by DART-MS/MS. At least two MS/MS transitions (quantitative and qualitative) were monitored for all of the analytes and internal standards. They were initially selected on the basis of the maximum signal and minimal interferences from the ambient environment. To identify isobaric interferences between defined transitions, QuickStrip HTS-96 cards were prepared with individual analyte standards as described above, followed by DART-MS/MS analysis including all analytes in the method. The resolutions of quadrupoles Q1 and Q3 were set to 0.7. The DART ionization conditions for the fragments were optimized. The DART cone temperature and gas stream temperature were 350 °C and 375 °C, respectively, except for FLU (275 °C and 300 °C, respectively). The detector was set to dynamic mode, and the collision-induced dissociation pressure was 2.0 mtorr (0.27 Pa). The DART cone voltage and gas pressure were set to 50 V and 23 psi (159 kPa), respectively. DART was operated in linear scan mode (speed 0.5 mm/s, range 5.0 mm, as suggested by the manufacturer), and helium was used as the carrier gas. The sample acquisition time was 0.24 min. Monitored transitions and collision energies (CEs) for the analytes and respective internal standards are listed in Table 1.

为鉴定独特的 MS/MS 跃迁,使用自动多反应监测(MRM)优化功能,将分析物及相关内标的标准溶液直接注入配备加热电喷雾电离(HESI)源的 EVOQ® DART-TQ+(德国不来梅)三重四极杆质谱仪。每种分析物采集五个跃迁,用于 DART-MS/MS 优化工作。对于 DART-MS/MS 分析,质谱仪配备集成的 DART JumpShot® HTS 系统电离源(德国不来梅)。为鉴定最佳 MS/MS 跃迁,将 3.5 µL 分析物及相关内标标准溶液的甲醇等分试样点样到 QuickStrip HTS-96 Sample Cards(德国不来梅)上,在 40 °C 下用氮气干燥 15 min,然后通过 DART-MS/MS 分析。对所有分析物和内标至少监测两个 MS/MS 跃迁(定量和定性)。最初根据最大信号和来自周围环境的最小干扰选择这些跃迁。为鉴定所定义跃迁之间的同量异位干扰,如上所述用单独分析物标准品制备 QuickStrip HTS-96 卡,随后进行包含方法中所有分析物的 DART-MS/MS 分析。四极杆 Q1 和 Q3 的分辨率设置为 0.7。对碎片的 DART 电离条件进行了优化。DART 锥孔温度和气流温度分别为 350 °C 和 375 °C,但 FLU 除外(分别为 275 °C 和 300 °C)。检测器设置为动态模式,碰撞诱导解离压力为 2.0 mtorr(0.27 Pa)。DART 锥孔电压和气体压力分别设置为 50 V 和 23 psi(159 kPa)。DART 以线性扫描模式运行(速度 0.5 mm/s,范围 5.0 mm,按制造商建议),并使用氦气作为载气。样品采集时间为 0.24 min。分析物及各内标的监测跃迁和碰撞能量(CE)列于表 1。

*本文内容非商业广告,仅供专业人士参考!